SOTCJ0880ACCF - Flue gas probe
Replacement for Eva Calòr Adele, Agnese, Alex, Alice, Alina, Andrea, Anita, Anna, Asia, Barbara, Beatrice, Betty, Catria, Camilla, Cecilia, Cerino, Cerino 49, Cesare, Cloè, Dado, Daniel, Dante, Deborah, Diana, Donatello, Duna, Eddy, Elena, Elisa, Elsa, Enrica, Erika, Erminy, EV 14, EV 24, EV 34, EV 50, Evelyn, Fiamma, Flavia, Flora, Frida, Gaia, Gemma, Giada, Greta, Heidi, Hermes, Ida, Ines, Irma, Ivo, Kali, Karen, Kendra, Laila, Laura, Lea, Leonardo, Letizia, Linda, Lucia, Lory, Lucilla, Mara, Maria, Matilde, Milly, Mirta, Nadia, Naomi, Nerella, Nico, Nina, Nora, Paola, Perla, Petra, Rita, Rosy, SB 80, Sissi, Sofia, Sole, Sonia, Tea, Tina, Tondè, Tommy, TS 80, Venere, Vera, Zelda, Zephiro 9, Zoe.
Replacement for Punto Fuoco Adria, Alessia, Alessio, Alyssa, Ariel, Bolonia, Camilla, Catria 9, Daria, Delia, Dora, Doroty, Giorgina, Ilaria, Irina, Lara, Lia, Licia, Lidia, Lilli, Luana, Luisa, Marisa, Martina, Mary, Matilde, Minni, Nella, Nia, Nicole, Noa, Sara, Poly, Prezzemolo, Sara, Stella, Susy, Titti, Thelma, Veronica, Zita.
The SOTCJ0880ACCF smoke probe from Micro Nova is an original spare part for Eva Calor and Punto Fuoco pellet stoves.
Original spare part for pellet stoves Adele, Agnese, Alex, Alice, Alina, Andrea, Anita, Anna, Asia, Barbara, Beatrice, Betty, Catria, Camilla, Cecilia, Cerino, Cerino 49, Cesare, Cloè, Dado, Daniel, Dante, Deborah, Diana, Donatello, Duna, Eddy, Elena, Elisa, Elsa, Enrica, Erika, Erminy, EV 14, EV 24, EV 34, EV 50, Evelyn, Fiamma, Flavia, Flora, Frida, Gaia, Gemma, Giada, Greta, Heidi, Hermes, Ida, Ines, Irma, Ivo, Kali, Karen, Kendra, Laila, Laura, Lea, Leonardo, Letizia, Linda, Lucia, Lory, Lucilla, Mara, Maria, Matilde, Milly, Mirta, Nadia, Naomi, Nerella, Nico, Nina, Nora, Paola, Perla, Petra, Rita, Rosy, SB 80, Sissi, Sofia, Sole, Sonia, Tea, Tina, Tondè, Tommy, TS 80, Venere, Vera, Zelda, Zephiro 9, Zoe.
Original spare part for pellet stoves Adria, Alessia, Alessio, Alyssa, Ariel, Bolonia, Camilla, Catria 9, Daria, Delia, Dora, Doroty, Giorgina, Ilaria, Irina, Lara, Lia, Licia, Lidia, Lilli, Luana, Luisa, Marisa, Martina, Mary, Matilde, Minni, Nella, Nia, Nicole, Noa, Sara, Poly, Prezzemolo, Sara, Stella, Susy, Titti, Thelma, Veronica, Zita.
While the room probe measures the degrees of the air in the room, the SOTCJ0880ACCF flue gas probe is used to monitor extreme temperatures inside the stove's flue gas exhaust.
The SOTCJ0880ACCF probe detects temperatures from a minimum of 30 to a maximum of 600 degrees Celsius.
It communicates to the stove that it is actually on and adjusts the smoke extractor speed to optimize combustion.
If it detects excessively high temperatures, it triggers the safety alarm on the display and turns off the stove to prevent structural damage.
The SOTCJ0880ACCF probe is made of AISI 316 steel. The cable is 85 centimeters long. It features a fixed flange with a clamp that screws it into the exhaust fan duct and locks it securely.
The probe must be changed if the following smoke probe alerts, smoke probe error and ignition failure appear on the stove.



